Latest Program :

Mirror image coordinate selection check Okuma Control


G62  Z-axis mirror image coordinate selection check

          Whether the Z-axis program coordinate system is used as the fundamental or mirror image coordinate system is instructed at the head of program. Actually, the direction of coordinate system is selected by the parameter and, when the program instruction mismatches with the parameter selection, an alarm occurs.

[Command format]

          G62 Z0:  Selection of fundamental coordinate system
          G62 Z1:  Selection of mirror image coordinate system

[Note]
          1. Since this G code is used to collate the machining program with the mirror image selection parameter for safety reasons, omitting this code does not result in an alarm.
          2. This code is effective for the twin-spindle machine.

[Applicable specification]  LT machine